Add to Cart
Modular Vehicle testing equipment environmental walk in freezer test chamber Cooling Room
Modular Vehicle testing equipment environmental walk in freezer test chamber Cooling RoomTechnical Parameters:
Model | TAR-volume |
Inner Dimensions(cm) | Customers designated space size and design |
Temperature Range | RT+10℃~80℃(80℃ ~150℃ is optional) |
Indication Resolution / Distribution Uniformity of Temperature | 0.1℃ /±2.5℃; |
Control Accuracy of Temperature | ±0.5℃; |
Temperature Rising Speed Rate | Temperature rising speed: approx. 0.1~3.0 (℃/min) |
Cooling System | Refrigeration by compressor, |
Protection Devices | Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection switch, over-temperature protection switch, fuses, fault warning system |
Optional Accessories | Slope for cart , Recorder |
Compressor | French Tecumseh Brand, Germany Bizer Brand |
Power | AC 380 V,50/60HZ ,3∮ 5 Lines |
Control System for walk in test chamber:
(1) P.I.D microcomputer automatic calculate temperature controller, PV/SV display at
the same time, set by press key. (Korea TEMI touch screen controller optional);
(2) 380V Solid state relay temperature output;
(3) Current Controller : SSR no contact relay
Air circulating System about walk in temperture chamber:
(1)Forced horizontal air circulation system;
(2)Temperature resistant special motor with long axis, and power 1/2 HP 50HZ
(3) Built-in adjustable wind guide plate
Dimensions with walk in temperature chamber
Internal Dimension (W×H×D):W4750×D5300×H4600 (mm)
External Dimension(W×H×D):W5750×D5900×H4900 (mm)
3. Temperature:0℃ ~ -5℃ (Temp.&Time Setting freely, automatic timing when reach the
preset temp., and automatic stop temperature when time’s up). Temp. Control Accuracy: ±0.5℃
Temp.Analytic Accuracy:0.1℃
Material of Construction:
(1)Interior material is SUS#304 stainless steel
(2)Exterior material is paint coated steel plate
(3) Insulation Material of imported fire-proof rock wool
(4) Heating Medium: electric heating tube
(5)TRAY: 2 NO. STAINLESS STEEL MADE
Control System
(1) P.I.D microcomputer automatic calculate temperature controller, PV/SV display at
the same time, set by press key. (Korea TEMI touch screen controller optional);
(2) 380V Solid state relay temperature output;
(3) Current Controller : SSR no contact relay