Add to Cart
salt spray test chamber SH-120.pdf
Astm B117 Salt Spray Corrosion Test Chamber for Clay Continuous Spraying Test
Model | SH-60 | SH-90 | SH-120 | SH-160 | SH-200 | ||||
Internal Dimension WxHxD (mm) | 600x400x450 | 900x500x600 | 1200x500x800 | 1600x500x800 | 2000x500x800 | ||||
External Dimension WxHxD (mm) | 1100x600x1200 | 1400x950x1200 | 1900x1300x1400 | 2300x1300 x1400 | 2700x1500 x1500 | ||||
Lab Temperature | Saline test (NSS ACSS) 35±1 °C ;Corrosion Test (CASS)50±1 °C | ||||||||
Pressure Bucket Temperature | Saline test method (NSS ACSS) 47±1 °C / Corrosion Test (CASS)63±1 °C | ||||||||
Lab Capacity(L) | 108 | 270 | 480 | 640 | 800 | ||||
Saline Capacity(L) | 15 | 25 | 40 | 40 | 40 | ||||
Saline Concentration | 5% concentration of NaCl, or every Liter 5% NaCl add 0.26g CuCl2H2O | ||||||||
Compressed Air Pressure(Kgf) | 1.0~6.0 | ||||||||
Spray Volume | 1.0~2.0ml /80cm2 /h(working at least 16 hours, and take the average value) | ||||||||
Spray Form | Continuous Spraying or Programmable Spraying | ||||||||
Power | AC220V 1 phase 3 lines15A | ||||||||
Weight(Kg) | 65 | 80 | 120 | 160 | 200 |
Continuous Spraying Salt Spray Corrosion Test for Clay ASTM B117 is used to test the corrosive resistance of products whose the surface was treated with paint, electroplating, inorganic and organic film, anode handling,anti-rust oil,etc.
Test standard:
1.GB/T 2423.17-1993 salt spray test
2.GB/T 2423.18-2000 salt spray test
3.GB/T 10125-1997 salt spray test
4.ASTM.B117-97 salt spray test
5.JIS H8502 salt spray test
6.IEC68-2-11 salt spray test
7.IEC68-2-52 1996 salt spray test
8.GB.10587-89 salt spray test
9.CNS.4158 salt spray test
10.CNS.4159 CASS Accelerated acetic acid copper salt spray test
11..GB/T 12967.3-91 CASS Accelerated acetic acid copper salt spray test